Product Description
Level Gauge - Tubular type with Isolation Valves at front
Type | Range | Accuracy | Specification |
| Tubular Glass | 0-300mm up to 0-1500 mm | | Side Mounted Transparent Glass Tube for liquids |
| Reflex | 150mm up to 1500mm | | Side Mounted Transparent Glass Tube for high pressure application |
| Pointer Type Mechanical Level Gauge | 0 to 1.5 meters and 0 to 2.5 meter | | Top Mounited Mechanical Level Indication with ease in mounting (in PP construction) |
| Follower Float | 0 to 500 mm to 0-1500mm | Approx 2% | Side or top mounted Mechanical level Indication having Magnetic Float |
| Bi-color Magnets | 0 to 500 mm up to 0-1500 mm | Approx 4 mm | Side or top mounted Mechanical level Indication for Liquids using Rolling Magnets and Megnetic Float |
| Float and Board | 0-2 meters up to 0-25 meters | Approx 5% | Float operated mechanical level Indicator for liquid storage tank |
| Float Type (Analogue Output) | 0-300 mm up to 0-3000mm | Approx 3 mm | Magnetic Float Operated Liquid level Indicator using Bypass assembly or, Top Mounting Type In tanks |
| Capacitance Type (Analogue Output) | 0-150 mm up to 0-15 meters | Approx 1% | Rod type or Rope type Sensor for Conductive or non-conductive liquids only |
| Poteniometric (Analogue Output) | 0-200 mm to 0-3000 mm | Approx 0.5% | Perfectly suitable and acceptable for food and pharma application |
| Diaphragm type/ Submersible Type (Analogue Output)) | Gravity pressure from 0-100mbar up to 0to 20 bar | Approx 1% | S.S Sensors and PP Cable-suitable for clear Liquids only. |
| Ultrasonic (Analogue Output) | 100-27400 mm | Approx 1% | Non Contact Level Sensor is not suitable for tanks having vacuum, Foam, high temperature and high pressure configurable measuring range. Compact instrument and available with Hygienic design and Configurable measuring range. |
| Radar / Micro Wave (Analogue Output) | 300-1000 mm to 300-3000 mm | Approx 0.5% | Non contact level sensor is suitable for almost all applications. Compact instrument and available with hygienic design and configurable measuring range |
Application : There are 4 typical applications for the level measuring Instruments
- For level indication Mechanically, where any electrical or battery supply wont be required
- For level sensing and digital indication of available level in the tank
- For level Indication and transmitter for remote indication or, control application
- Level measuring instruments are used very commonly in industries like chemical and petrochemical, paper and pulp, food and drugs, water transport and Beverage construction industries cement plants etc. p { margin-bottom: 0.25cm; line-height: 120%; }
Note :To receive quick response, please provide your basic requirement details and max.Application information.
Customizable and Reliable ConstructionDesigned to meet specific installation requirements, this tubular level gauge allows customization for center-to-center distance, measuring range, and process connections in both flanged and screwed end configurations. The use of borosilicate glass and resilient sealing materials such as PTFE, Neoprene, or Viton ensures durability and safety, even in demanding industrial applications.
Enhanced Safety and Protection FeaturesThis level gauge provides optional guard rods or shield plates to prevent glass damage during operation. Leak-proof performance is achieved with a compressible gland packing system, while integral isolation valves facilitate safe maintenance and easy draining or venting. All wetted parts comply with IS/ASTM standards to maximize safety and longevity.
FAQs of Level Gauge - Tubular type with Isolation Valves:
Q: How does the tubular type level gauge indicate liquid levels?
A: The gauge uses a transparent borosilicate glass tube, allowing operators to directly observe the actual liquid level inside tanks or vessels, providing an immediate and accurate visual reading.
Q: What benefits do isolation valves offer in this level gauge?
A: Integral ball or needle isolation valves enable safe isolation of the gauge for maintenance, draining, or venting, minimizing process interruption and enhancing operational safety.
Q: Where can this level gauge be installed and in which orientation?
A: The tubular level gauge is typically mounted vertically on tanks or vessels. Its center-to-center and process connection sizes can be customized to fit specific installation points in a wide range of industrial applications.
Q: What is the maximum operating temperature and pressure of this gauge?
A: Standard models operate up to 150C and withstand pressures up to 10 kg/cm; higher ratings can be provided on request to suit unique application needs.
Q: How is glass protection achieved in this gauge?
A: Optional guard rods or shield plates are available to protect the borosilicate glass tube from accidental impact, ensuring prolonged service life in harsh environments.
Q: What standards and materials ensure the gauges reliability?
A: All wetted parts and glass conform to IS/ASTM standards, with options for brass, cast iron, or stainless steel construction, as well as seals made from PTFE, Neoprene, Viton, or materials specified by the process.